Phase Relays

Elektro Plast Phase Relay Earth Leakage 16A Bipolar

The Elektro Plast 87.902 two-pole DIN rail circuit breaker combines protection against leakage currents and overcurrents, also covering overloads and short circuits. It is installed on a DIN rail and...

The Elektro Plast 87.902 two-pole DIN rail circuit breaker combines protection against leakage currents and overcurrents, also covering overloads and short circuits. It is installed on a DIN rail and has a B trip curve.

  • Type: Residual current circuit breaker
  • Rated voltage: 230 V
  • Rated current: 16 A
  • Number of poles: 2 (1P+N)
  • Residual current: 30 mA
  • Type: AC
  • ...
See Description & Specifications See Description & Specifications
23 90 €
Delivery Fri, 27 Nov - Tue, 01 Dec
4,50 € shipping cost
Sent from Greece
From Getters 4.5 (117)
What if it breaks?

You're covered by the statutory 2-year warranty. Contact us and we'll handle the entire process with the store, ensuring your issue is resolved with prompt support through a repair, replacement, or refund. Learn more

What if I change my mind?

No problem, as long as it's within 14 days. We'll come pick it up or you can choose the Skroutz Point that suits you, completely free for up to 2 times per year, and we'll refund your money. Get Skroutz Plus to enjoy unlimited free returns.

Learn more about invoicing
Questions

Description & Specifications

The Elektro Plast 87.902 two-pole DIN rail circuit breaker combines protection against leakage currents and overcurrents, also covering overloads and short circuits. It is installed on a DIN rail and has a B trip curve.

  • Type: Residual current circuit breaker
  • Rated voltage: 230 V
  • Rated current: 16 A
  • Number of poles: 2 (1P+N)
  • Residual current: 30 mA
  • Type: AC
  • Trip curve: B
  • Protection rating: IP20
  • Operating temperature: -5 to 40 °C
  • Dimensions: 36 × 85 × 50 mm
  • Net weight: 190 g
  • Power loss: 4.5 W
  • Surge current withstand: 3 kA
  • Insulation voltage: 500 V
  • Impulse withstand voltage: 4 kV
  • Conductor cross-section: 1–16 mm² for solid or stranded conductors
  • Service life: 60 months

Manufacturer

Type
Earth Leakage
Number of Poles
2
Nominal Voltage
16 A
Leakage Current
30 mA
with Energy Consumption Meter
No
with Timer
No
Type of Residual Current Relay
Type AC

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

23,90 €
4,50 €   shipping cost