Electrical Panel Push Buttons Switches

Sinotimer Rail Switch 230V 50A

Functions:

  • Overvoltage protection
  • Undervoltage protection
  • Voltage display (individual measurement of ABC phases)
  • Three-phase unbalance protection
  • Phase sequence protection (protection against phase...

Functions:

  • Overvoltage protection
  • Undervoltage protection
  • Voltage display (individual measurement of ABC phases)
  • Three-phase unbalance protection
  • Phase sequence protection (protection against phase reversal)
  • Line disconnection protection
  • Error protection
  • Adjustable overvoltage protection setpoint
  • Adjustable overvoltage reset point
  • Adjustable overvoltage...
See full description See full description
The product is not available for shipping to the selected country.

Description

Description

Functions:

  • Overvoltage protection
  • Undervoltage protection
  • Voltage display (individual measurement of ABC phases)
  • Three-phase unbalance protection
  • Phase sequence protection (protection against phase reversal)
  • Line disconnection protection
  • Error protection
  • Adjustable overvoltage protection setpoint
  • Adjustable overvoltage reset point
  • Adjustable overvoltage protection response time
  • Adjustable undervoltage protection setpoint
  • Adjustable undervoltage reset point
  • Adjustable undervoltage protection response time
  • Adjustable three-phase unbalance protection setpoint
  • Adjustable three-phase unbalance protection response time
  • Delay time after setting
  • Adjustable fault reset time
  • Recovery mode selection
  • Real data reset

Product parameters:

  • Model number: STVP-932
  • Power supply: three-phase 4-wire 230V / 400VAC 50 / 60Hz
  • Maximum load current: 50A
  • Overvoltage protection setpoint range: 221V ~ 300V adjustable (default: 280V)
  • Overvoltage reset point range: 220V ~ 299V (default: 250V)
  • Overvoltage protection response time: 0.1 ~ 10 seconds (default: 0.2s)
  • Undervoltage protection setpoint range: 150V ~ 219V adjustable (default: 160V)
  • Undervoltage reset point range: 151V ~ 220V (default: 180V)
  • Undervoltage protection response time: 0.1 ~ 10 seconds (default: 0.2s)
  • Three-phase unbalance protection setpoint: 10% ~ 50% ~ OFF (default: 20%)
  • Three-phase unbalance protection response time: 0.1 ~ 10 seconds (default: 1s)
  • Activation delay time: 2-255 seconds (default: 2s)
  • Recovery delay time: 2 ~ 600 seconds (default: 60s)
  • Display type: LCD
  • Dimensions: 72 * 65 * 80 mm
  • Installation: Mounting on 35 mm DIN rail

Manufacturer

See full description

Specifications

Specifications

Specifications

Nominal Voltage
230 V
Rated Voltage
50 A

Features & Functions

WiFi
No

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications
Questions

Questions

Do you have a question about the product?

Those users who have this product can help you

Ask for the product

Description & Specifications

Functions:

  • Overvoltage protection
  • Undervoltage protection
  • Voltage display (individual measurement of ABC phases)
  • Three-phase unbalance protection
  • Phase sequence protection (protection against phase reversal)
  • Line disconnection protection
  • Error protection
  • Adjustable overvoltage protection setpoint
  • Adjustable overvoltage reset point
  • Adjustable overvoltage protection response time
  • Adjustable undervoltage protection setpoint
  • Adjustable undervoltage reset point
  • Adjustable undervoltage protection response time
  • Adjustable three-phase unbalance protection setpoint
  • Adjustable three-phase unbalance protection response time
  • Delay time after setting
  • Adjustable fault reset time
  • Recovery mode selection
  • Real data reset

Product parameters:

  • Model number: STVP-932
  • Power supply: three-phase 4-wire 230V / 400VAC 50 / 60Hz
  • Maximum load current: 50A
  • Overvoltage protection setpoint range: 221V ~ 300V adjustable (default: 280V)
  • Overvoltage reset point range: 220V ~ 299V (default: 250V)
  • Overvoltage protection response time: 0.1 ~ 10 seconds (default: 0.2s)
  • Undervoltage protection setpoint range: 150V ~ 219V adjustable (default: 160V)
  • Undervoltage reset point range: 151V ~ 220V (default: 180V)
  • Undervoltage protection response time: 0.1 ~ 10 seconds (default: 0.2s)
  • Three-phase unbalance protection setpoint: 10% ~ 50% ~ OFF (default: 20%)
  • Three-phase unbalance protection response time: 0.1 ~ 10 seconds (default: 1s)
  • Activation delay time: 2-255 seconds (default: 2s)
  • Recovery delay time: 2 ~ 600 seconds (default: 60s)
  • Display type: LCD
  • Dimensions: 72 * 65 * 80 mm
  • Installation: Mounting on 35 mm DIN rail

Manufacturer

Specifications

Nominal Voltage
230 V
Rated Voltage
50 A

Features & Functions

WiFi
No

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.