Basic Battery Information:
- Weight: ~ 1.25 kg
- Height: 160 mm (210 mm with thread)
- Width: 66 mm
- Depth: 66 mm
- Nominal Voltage: 2.3 V
- Capacity: 40 Ah
- Maximum Discharge Current 10Sec 20C: 800 A
- Optimal Discharge Current: 40 A
- Maximum Charge Current: 400 A
- Optimal Charge Current: 40 A
- Operating Temperature: -55°C - 65°C
- Final Charge Voltage: 2.5V - 2.65V (manufacturer specification 2.8V)
- Final Discharge Voltage: 1.8V - 2.0V (manufacturer specification 1.5V)
- Maintenance Charging: not recommended, can be set to 2.25V/cell with solar charge controllers.
Notes on LTO Cells:
- The optimal operating range of YINLONG LTO cells is between 2.0V and 2.5V.
- When cells are charged above 2.5V, the voltage increases more steeply, above 2.6V very steeply.
- The situation is similar when discharging below 2.0V!
- It is very important to use a good active balancer for LTO cells connected in series.
- When working with very high currents (charging or discharging), it may be necessary to further limit the operating range to avoid large voltage increases or decreases.
Manufacturer
OEM- Size
- A
- Voltage
- 2.3 V
- Packaging
- 1 pcs
Important information
Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.