Electrical Panel Push Buttons Switches

Schneider Electric 3-Poles Panel Push Switch 230V 40A

Surge Protector iPF40 3P+N A9L15688

Product Type: Surge Protection Device

Number of Poles: 3P + N

Type of Surge Diverter: Electric Power Distribution Network

Grounding System: TN-S

Category of Surge...

Surge Protector iPF40 3P+N A9L15688

Product Type: Surge Protection Device

Number of Poles: 3P + N

Type of Surge Diverter: Electric Power Distribution Network

Grounding System: TN-S

Category of Surge Diverter: Type 2

Lightning Protection Technology: MOV+GDT

  • [Ue] rated operating voltage: 230 V ( 10%) AC 50/60 Hz, 400 V ( 10%) AC 50/60 Hz
  • Nominal Discharge...
See full description See full description
92 03
93 Coins 93 Coins
Delivery Fri, 02 Oct - Tue, 06 Oct
3,50 € to a Skroutz Point or 4,50 € to an address
Do you want it with Free shipping?
Sent from Greece
From Getters 4.5 (109)
What if it breaks?

You're covered by the statutory 2-year warranty. Contact us and we'll handle the entire process with the store, ensuring your issue is resolved with prompt support through a repair, replacement, or refund.

What if I change my mind?

No problem, as long as it's within 14 days. We'll come pick it up or you can choose the Skroutz Point that suits you, completely free for up to 2 times per year, and we'll refund your money. Get Skroutz Plus to enjoy unlimited free returns.

Learn more about invoicing

Description

Description

Surge Protector iPF40 3P+N A9L15688

Product Type: Surge Protection Device

Number of Poles: 3P + N

Type of Surge Diverter: Electric Power Distribution Network

Grounding System: TN-S

Category of Surge Diverter: Type 2

Lightning Protection Technology: MOV+GDT

  • [Ue] rated operating voltage: 230 V (± 10%) AC 50/60 Hz, 400 V (± 10%) AC 50/60 Hz
  • Nominal Discharge Current:
    • Common mode: 15 kA L/PE
    • Common mode: 15 kA N/PE
    • Differential mode: 15 kA L/N
  • Maximum Discharge Current:
    • Common mode: 40 kA L/PE
    • Common mode: 40 kA N/PE
    • Differential mode: 40 kA L/N
  • [Uc] highest continuous operating voltage:
    • Common mode: 260 V N/PE
    • Common mode: 340 V L/PE
    • Differential mode: 340 V L/N
  • Voltage Protection Level:
    • 1.5 kV type 2 common mode N/PE
    • 1.5 kV type 2 differential mode L/N
  • [Ut] instantaneous overvoltage:
    • Withstand: 337 V L/N for 5s
    • Withstand: 442 V L/PE for 5s
    • Withstand: 1200 V N/PE for 200 ms
    • Withstand: 1453 V L/PE for 200 ms
  • Disconnecting Device Type: Connected circuit breaker iK60N 40 A Icu 6 kA curve C
  • Short-circuit Resistance: 25 kA
  • Local Indication Color: LED: green/red
  • Mounting Method: Snap-in, DIN rail
  • Dimensions: Height 81.4 mm, Width 72 mm, Depth 69 mm
  • Product Weight: 0.355 kg
  • Color: White (RAL 9003)

Manufacturer

See full description

Specifications

Specifications

Specifications

Number of Poles
3
Nominal Voltage
230 V
Rated Voltage
40 A

Features & Functions

WiFi
No

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications
Questions

Questions

Do you have a question about the product?

1 user has this product and can help you

Ask for the product

Description & Specifications

Surge Protector iPF40 3P+N A9L15688

Product Type: Surge Protection Device

Number of Poles: 3P + N

Type of Surge Diverter: Electric Power Distribution Network

Grounding System: TN-S

Category of Surge Diverter: Type 2

Lightning Protection Technology: MOV+GDT

  • [Ue] rated operating voltage: 230 V (± 10%) AC 50/60 Hz, 400 V (± 10%) AC 50/60 Hz
  • Nominal Discharge Current:
    • Common mode: 15 kA L/PE
    • Common mode: 15 kA N/PE
    • Differential mode: 15 kA L/N
  • Maximum Discharge Current:
    • Common mode: 40 kA L/PE
    • Common mode: 40 kA N/PE
    • Differential mode: 40 kA L/N
  • [Uc] highest continuous operating voltage:
    • Common mode: 260 V N/PE
    • Common mode: 340 V L/PE
    • Differential mode: 340 V L/N
  • Voltage Protection Level:
    • 1.5 kV type 2 common mode N/PE
    • 1.5 kV type 2 differential mode L/N
  • [Ut] instantaneous overvoltage:
    • Withstand: 337 V L/N for 5s
    • Withstand: 442 V L/PE for 5s
    • Withstand: 1200 V N/PE for 200 ms
    • Withstand: 1453 V L/PE for 200 ms
  • Disconnecting Device Type: Connected circuit breaker iK60N 40 A Icu 6 kA curve C
  • Short-circuit Resistance: 25 kA
  • Local Indication Color: LED: green/red
  • Mounting Method: Snap-in, DIN rail
  • Dimensions: Height 81.4 mm, Width 72 mm, Depth 69 mm
  • Product Weight: 0.355 kg
  • Color: White (RAL 9003)

Manufacturer

Specifications

Number of Poles
3
Nominal Voltage
230 V
Rated Voltage
40 A

Features & Functions

WiFi
No

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

92,03 €