Phase Relays

Liquid Level Control Relay Pz-829 Rc

Liquid level control relay sensors 16A 2P 1-100kOhm 3 (PZ-829 RC)

Two states (min/max). With adjustable sensitivity, the PZ-829 relays are used to detect the presence of electrically conductive...

Liquid level control relay sensors 16A 2P 1-100kOhm 3 (PZ-829 RC)

Two states (min/max). With adjustable sensitivity, the PZ-829 relays are used to detect the presence of electrically conductive liquids at the installation levels of flood detectors. They allow the maintenance of the minimum and maximum condition of the controlled liquid within the range...

See full description See full description
94 15
95 Coins 95 Coins
Delivery Wed, 12 Aug - Tue, 18 Aug
4,00 € to a Skroutz Point or 5,00 € to an address
Do you want it with Free shipping?
Sent from Greece
From Getters 4.5 (109)
What if it breaks?

You're covered by the statutory 2-year warranty. Contact us and we'll handle the entire process with the store, ensuring your issue is resolved with prompt support through a repair, replacement, or refund.

What if I change my mind?

No problem, as long as it's within 14 days. We'll come pick it up or you can choose the Skroutz Point that suits you, completely free for up to 2 times per year, and we'll refund your money. Get Skroutz Plus to enjoy unlimited free returns.

Description

Description

Liquid level control relay sensors 16A 2P 1-100kOhm 3 (PZ-829 RC)

Two states (min/max). With adjustable sensitivity, the PZ-829 relays are used to detect the presence of electrically conductive liquids at the installation levels of flood detectors. They allow the maintenance of the minimum and maximum condition of the controlled liquid within the range specified by the user.

When the liquid level drops to the MIN state (i.e., the MIN and COM electrodes are open), the MIN contact will change to position 11-12, while the MAX contact remains at position 8-9. After reaching the MAX state (the MAX and COM electrodes are short-circuited), the MIN relay contact changes to position 11-10 and the MAX contact to position 8-7.

Connection:

  • Electrode sensors (3 pieces) connected with wire with a core diameter of up to 1 mm² and a maximum length of 100 m.
  • Terminals 4-5-6 are separated from the network.

Technical specifications:

  • Power supply voltage: 230 V
  • Actuator element: AC 2 × relay
  • Maximum load current: 2 × 16 AC
  • Contact configuration: 2 × NO/NC
  • Contact isolation: YES
  • Sensitivity: adjustable 1÷100 kΩ
  • Output measurement voltage: 6 V
  • Contact switching delay for the MAX point: max 5 s
  • Detector terminals isolated from the network with a transformer
  • Screw terminal connection: 4.0 mm²
  • Tightening torque: 0.5 Nm
  • Power consumption: 1.1 W
  • Operating temperature: -25 ÷ 50 °C
  • Dimensions: 3 units (52 mm) on 35 mm rail
  • Protection level: IP20

Manufacturer

See full description

Specifications

Specifications

Type
Power
Number of Poles
2
Voltage
230 V
Nominal Voltage
16 A
with Energy Consumption Meter
No
with Timer
No

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications
Questions

Questions

Do you have a question about the product?

Those users who have this product can help you

Ask for the product

Description & Specifications

Liquid level control relay sensors 16A 2P 1-100kOhm 3 (PZ-829 RC)

Two states (min/max). With adjustable sensitivity, the PZ-829 relays are used to detect the presence of electrically conductive liquids at the installation levels of flood detectors. They allow the maintenance of the minimum and maximum condition of the controlled liquid within the range specified by the user.

When the liquid level drops to the MIN state (i.e., the MIN and COM electrodes are open), the MIN contact will change to position 11-12, while the MAX contact remains at position 8-9. After reaching the MAX state (the MAX and COM electrodes are short-circuited), the MIN relay contact changes to position 11-10 and the MAX contact to position 8-7.

Connection:

  • Electrode sensors (3 pieces) connected with wire with a core diameter of up to 1 mm² and a maximum length of 100 m.
  • Terminals 4-5-6 are separated from the network.

Technical specifications:

  • Power supply voltage: 230 V
  • Actuator element: AC 2 × relay
  • Maximum load current: 2 × 16 AC
  • Contact configuration: 2 × NO/NC
  • Contact isolation: YES
  • Sensitivity: adjustable 1÷100 kΩ
  • Output measurement voltage: 6 V
  • Contact switching delay for the MAX point: max 5 s
  • Detector terminals isolated from the network with a transformer
  • Screw terminal connection: 4.0 mm²
  • Tightening torque: 0.5 Nm
  • Power consumption: 1.1 W
  • Operating temperature: -25 ÷ 50 °C
  • Dimensions: 3 units (52 mm) on 35 mm rail
  • Protection level: IP20

Manufacturer

Type
Power
Number of Poles
2
Voltage
230 V
Nominal Voltage
16 A
with Energy Consumption Meter
No
with Timer
No

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

94,15 €