Product Design Type: RCCB VI
Number of poles: 4P
Installation: DIN rail
Electrical characteristics
- Rated operating voltage Ue (AC): 230/400V
- Rated frequency: 50 Hz
- Rated insulation voltage Ui: 500V
- Rated impulse withstand voltage Uimp: 4 kV
- Rated residual operating current dI: 300 mA
- Rated discharge current (at 8/20µs): 0.25 kA
- Rated making and breaking capacity Im: 1.5 kA
- Rated short-circuit current under conditions Inc according to PN-EN 61008-1: 6 kA
Current/Temperature
- Rated current at -15°C: 40A
- Rated current at -20°C: 40A
- Rated current at 0°C: 40A
- Rated current at 10°C: 40A
- Rated current at -10°C: 40A
- Rated current at 15°C: 40A
- Rated current at 20°C: 40A
- Rated current at 25°C: 40A
- Rated current at -25°C: 40A
- Rated current at 30°C: 40A
- Rated current at 35°C: 40A
- Rated current at 40°C: 40A
- Rated current at 45°C: 40A
- Rated current at 5°C: 40A
- Rated current at -5°C: 40A
- Rated current at 50°C: 40A
- Rated current at 55°C: 40A
- Rated current at 60°C: 40A
- Rated current at 65°C: 40A
- Rated current at 70°C: 40A
Power
- Total power losses for rated current: 8.1 W
- Power losses per pole for rated current: 3.6W
Actuation
- Short delay: NO
Elasticity
- Electrical endurance (number of cycles): 2000
- Mechanical endurance (number of cycles): 4000
Dimensions
- Product depth: 70 mm
- Product height: 83 mm
- Product width: 70 mm
Installation / Assembly
- Tightening torque: 2.8 Nm
Connection
- Flexible cable cross-section (cord) at terminal: 16 mm²
- Rigid conductor cross-section (wire) at terminal: 25 mm²
- Type of connection: with screw
Equipment
- Additional accessories: Yes
Standard
- Standard: EN 61008-1
- European RoHS directive: compliant
- European WEEE directive: Yes
Safety
- Protection degree: IP20
- Type of residual current device: AC
Terms of Use
- Pollution degree according to IEC 60664 / IEC 60947-2: 2
- Storage temperature: -55 to 70 °C
Designation
- Device group: CF{Number of poles} 4 . {Rated current [A]} 40 . {Sensitivity} AC . {Input protection [IP]} IP20 . {Rated residual current [A]} 0.3
- Type
- Earth Leakage
- Number of Poles
- 4
- Voltage
- 400 V
- Nominal Voltage
- 40 A
- Leakage Current
- 300 mA
- with Energy Consumption Meter
- No
- with Timer
- No
- Type of Residual Current Relay
- Type AC
Important information
Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.