Industrial Switches

Hager X160 Industrial Automatic Power Αυτόματος Διακόπτης Ισχύος 25kΑ 3P 160Α Ρυθμιζόμενος HHA160H

The Hager X160 circuit breaker has a rated current of 160 A and a breaking capacity of 25 kA. The thermal trip can be set to 0.63, 0.8 and 1, and the trip type is TM.

  • Type: Circuit breaker
  • Poles:...

The Hager X160 circuit breaker has a rated current of 160 A and a breaking capacity of 25 kA. The thermal trip can be set to 0.63, 0.8 and 1, and the trip type is TM.

  • Type: Circuit breaker
  • Poles: 3P3D
  • Rated current: 160 A
  • Breaking capacity: 25 kA
  • Rated operational voltage (AC): 220/415 V
  • Rated insulation voltage: 690 V
  • Impulse withstand voltage: 8 kV
  • Rated...
See full description See full description
176 06 €
Lowest price '26
Delivery Thu, 17 Dec - Mon, 21 Dec
3,50 € to a Skroutz Point or 4,50 € to an address
Do you want it with Free shipping?
Sent from Greece
From Papantoniou 4.6 (31)
What if it breaks?

You're covered by the statutory 2-year warranty. Contact us and we'll handle the entire process with the store, ensuring your issue is resolved with prompt support through a repair, replacement, or refund. Learn more

What if I change my mind?

No problem, as long as it's within 14 days. We'll come pick it up or you can choose the Skroutz Point that suits you, completely free for up to 2 times per year, and we'll refund your money. Get Skroutz Plus to enjoy unlimited free returns.

Learn more about invoicing

Description

Description

The Hager X160 circuit breaker has a rated current of 160 A and a breaking capacity of 25 kA. The thermal trip can be set to 0.63, 0.8 and 1, and the trip type is TM.

  • Type: Circuit breaker
  • Poles: 3P3D
  • Rated current: 160 A
  • Breaking capacity: 25 kA
  • Rated operational voltage (AC): 220/415 V
  • Rated insulation voltage: 690 V
  • Impulse withstand voltage: 8 kV
  • Rated frequency: 50/60 Hz
  • Thermal trip setting: 0.63/0.8/1
  • Trip type: TM
  • Modules: 4.5
  • Operating temperature: -25 to 70 °C
  • Storage temperature: -35 to 70 °C
  • Connection type: Screw connection
  • Stranded conductors: 4 / 70 mm²
  • Solid conductors: 4 / 95 mm²
  • Mechanical endurance: 4000 cycles
  • Electrical endurance: 1000 cycles
  • Total power loss at rated current: 43.8 W
  • Power loss per pole at rated current: 14.6 W
  • Tightening torque: 6 Nm
  • Rated short-circuit breaking capacity according to IEC 947.2 at 50 Hz: 80%

Manufacturer

See full description
Questions

Questions

Do you have a question about the product?

Those users who have this product can help you

Ask for the product

Description

The Hager X160 circuit breaker has a rated current of 160 A and a breaking capacity of 25 kA. The thermal trip can be set to 0.63, 0.8 and 1, and the trip type is TM.

  • Type: Circuit breaker
  • Poles: 3P3D
  • Rated current: 160 A
  • Breaking capacity: 25 kA
  • Rated operational voltage (AC): 220/415 V
  • Rated insulation voltage: 690 V
  • Impulse withstand voltage: 8 kV
  • Rated frequency: 50/60 Hz
  • Thermal trip setting: 0.63/0.8/1
  • Trip type: TM
  • Modules: 4.5
  • Operating temperature: -25 to 70 °C
  • Storage temperature: -35 to 70 °C
  • Connection type: Screw connection
  • Stranded conductors: 4 / 70 mm²
  • Solid conductors: 4 / 95 mm²
  • Mechanical endurance: 4000 cycles
  • Electrical endurance: 1000 cycles
  • Total power loss at rated current: 43.8 W
  • Power loss per pole at rated current: 14.6 W
  • Tightening torque: 6 Nm
  • Rated short-circuit breaking capacity according to IEC 947.2 at 50 Hz: 80%

Manufacturer

Hager - Industrial Switches Hager
176,06 €
3,50 € to a Skroutz Point